in an leisure park Wiehl
General inspection of a cycle bridge
Description
Within the framework of maintenance work, external defects in the structure of the wooden bridge were identified. We were then asked to examine the bridge within the framwork of the upcoming main inspection. Due to the lack of constructive wood protection, permanent humidification was found by deposits of foliage and the like, and the wood-destroying fungi offer good growth conditions. Even if only a few defects have been identified, they must be removed immediately, in order to increase the life of this structure.
Client
Landesbetrieb Straßenbau.NRW
Our service
Construction inspection, OSA and developpement of a renovation concept